Valve Pulse
Rate at which the valve dispenses shot. The Valve Pulse
is factory set to match the best ow characteristics of
the media (cast steel or cut wire). The typical operation
rate is 8 Hertz.
Test Connector
Provides access to
diagnostic voltages.
• 0 - 10 Vdc input
• 24 Vdc “Enable” input
• 6 - 20 Hertz pulse rate
• 0 Vdc common
Operation
Remote Valve Driver
Valve Driver Panel (behind the cover plate)
*Diagnostic LEDs
Valve On. Indicates when power is being sent to the MagnaValve’s electromagnet. When the
LED is on, the valve is on for full capacity ow rate. When the LED is o, the MagnaValve’s
permanent magnet has stopped the media ow. When the LED is blinking, the shot ow is
being regulated.
Vin > 0.25 Vdc. Indicates that an analog signal input greater than 0.25 Vdc has been received.
When this LED is o, no media ow is allowed. The input signal range is 0 -10 Vdc. At 10 Vdc,
the MagnaValve will open to full capacity. The relationship between the 0 -10 Vdc input signal
and actual ow rate is non-linear.
24 Vdc Enable. Indicates that the 24 Vdc Enable Signal has been received. When the LED is
o, the MagnaValve is inhibited and no shot will ow. This feature is provided as an on-o
action so the 0-10 Vdc input signal does not have to be disabled or removed.
24 Vdc Power. Indicates that 24 Vdc is available to operate the electromagnet for media ow.
It should always be available and able to supply 2 Amps.
All four LEDs must be on in order to have media ow.
Diagnostic LEDs*
The large knurled screw on the front cover of the Remote Valve Driver can be removed to gain
access to the factory adjustments. Please refer all adjustments to qualied personnel.