This Home Screen is an information center.
All 24V products using this control board have the ability to store data in 5 different tables.
This allows the use of different media types and sizes without recalibration.
Table Number: The first line of the screen has the table number in use. It is possible to add
special labels to the table, such as S-230, to help identification.
Flow Limit: The second line indicates the maximum calibrated flow rate for the valve. This
sets the output voltage to 10Vdc when the valve is flowing 20lb/min.
Valve Capacity: This gives the maximum flow of the valve with the selected shot size.
It also displays the following:
Current Temp.
Max. Temp.
Total Run Time.
Pwr Cycles (Number of times the valve has been powered on and off.)
A letter or number precedes all changeable functions. Press the appropriate letter/
number to change the function or to change screens.
2) Calibration Screen
3) Setup Screen
Press 3 and the following screen appears.